RISHABH PL96 DC Ground Fault Meter
The RISHABH PL96 DC Ground Fault Meter is a center-zero analog panel instrument intended for use in compatible SCR feeder panel monitoring circuits. It is configured with a dial marking of −100% to 0 to +100% and a basic moving-coil input range of −0.5mA to 0 to +0.5mA DC. The center-zero arrangement allows the pointer to move in either direction from the central reference point according to the polarity and magnitude of the applied DC signal.
This meter is suitable for replacement, maintenance and refurbishment of compatible drilling rig SCR electrical panels where the existing instrument has the same model, scale, input movement and mechanical dimensions. Technical compatibility should always be verified against the original meter, panel drawing and monitoring circuit before ordering.
Center-Zero Ground Fault Indication
The meter face is graduated from −100% through zero to +100%. Unlike a conventional meter that begins at zero on the left side, the pointer rests at the center of the scale when the monitored input signal is balanced or at its zero reference condition.
A signal of one polarity moves the pointer toward the negative side of the dial, while the opposite polarity moves it toward the positive side. This bidirectional indication helps panel operators observe both the magnitude and polarity of the signal supplied by the associated ground-fault monitoring circuit.
The percentage scale represents the calibrated indication required by the panel system. It should not automatically be interpreted as a direct measurement of leakage current, insulation resistance or fault current unless this relationship is confirmed by the original SCR panel documentation.
±0.5mA DC Basic Movement
The basic meter movement is specified as −0.5mA to 0 to +0.5mA DC. This means the instrument reaches the negative full-scale position when the appropriate −0.5mA DC input is applied and reaches the positive full-scale position at approximately +0.5mA DC, subject to the original calibration and circuit arrangement.
Because this is a low-current analog measuring instrument, it must be connected only to the intended monitoring or transducer circuit. It must not be connected directly to the main feeder power conductors or to an unverified voltage source. Applying an incorrect signal can damage the moving-coil mechanism or cause inaccurate indication.
Application in SCR Feeder Panels
The RISHABH PL96 DC Ground Fault Meter is specified for use in compatible SCR feeder panels. SCR systems are commonly used to control and distribute electrical power within drilling rig drive systems, including circuits associated with major DC equipment and panel monitoring functions.
Within the feeder panel, the ground-fault monitoring circuit provides an indication that helps operators identify abnormal conditions or changes in the monitored electrical system. The analog meter acts as a visual display for the low-level DC signal received from the related detection or control circuit.
The exact operational meaning of the positive and negative sides of the scale depends on the original system design. For this reason, wiring polarity, terminal identification and calibration must be checked against the existing panel schematic before the replacement meter is energized.
PL96 Analog Panel Meter Construction
The PL96 belongs to the RISHABH PL series of moving-coil analog panel meters. The moving-coil mechanism provides a linear response for DC current signals and supports clear visual indication across the scale. The 240-degree scale design provides an extended pointer travel and improved readability compared with instruments having a shorter angular scale.
The meter is designed for panel mounting and has a nominal front dimension of 96 × 96 mm. However, the panel cutout, installation depth, fixing arrangement and terminal positions should still be checked before ordering because the front dimension alone does not guarantee mechanical compatibility.
Technical Specifications
- Brand: RISHABH
- Series / Model: PL96
- Product type: DC Ground Fault Meter
- Instrument type: Analog moving-coil panel meter
- Zero position: Center zero
- Dial marking: −100% to 0 to +100%
- Basic movement: −0.5mA to 0 to +0.5mA DC
- Full-scale input: ±0.5mA DC
- Scale characteristic: Linear
- Nominal front size: 96 × 96 mm
- Panel application: Feeder Panel
- System application: SCR Control System
- Typical service: Replacement, repair and refurbishment
Compatibility Checks Before Ordering
Before ordering the RISHABH PL96 DC Ground Fault Meter, compare all available specifications with the existing instrument. The model number, dial wording, percentage range, polarity markings and basic movement must match the original application.
The following information should be checked:
- RISHABH PL96 model or equivalent identification
- Center-zero pointer position
- −100% to 0 to +100% dial marking
- −0.5mA to 0 to +0.5mA DC movement
- Terminal numbering and polarity
- Front dimensions and panel cutout
- Installation depth and fixing system
- Panel wiring diagram and circuit calibration
- Any special scale text, colored markings or revision details
A standard PL96 meter with a different input range or dial scale may look physically similar but will not necessarily operate correctly in the ground-fault monitoring circuit. Both the electrical movement and the customized dial must therefore be confirmed.
Installation and Safety
Installation should be carried out by qualified electrical personnel while the SCR feeder panel is fully isolated from all power sources. The absence of voltage must be verified before removing the existing instrument or touching its terminals.
Technicians should record the original wire positions and terminal polarity before disconnection. Reversing the connections may cause the pointer to move in the opposite direction. After installation, the meter indication should be tested using the approved panel procedure or a suitable calibrated low-current signal source.
Do not apply mechanical force to the pointer, alter the internal movement or connect the meter to a signal exceeding its rated input. The surrounding ground-fault PCB, wiring and sensing circuit should also be inspected if the original meter failed or displayed an abnormal reading.
Request a Quotation
To request a quotation, provide clear photographs of the front dial, rear terminals, side label and all model or serial markings. Please also provide the required quantity, SCR feeder panel details and the available electrical drawing. Oil Well Direct can review the supplied information to support technical matching before issuing an offer.
Official RISHABH datasheet for PL series 240-degree moving-coil analog panel meters, including PL96 dimensions, construction, DC measurement characteristics and ordering options.