{"id":2180,"date":"2026-07-17T00:54:32","date_gmt":"2026-07-17T00:54:32","guid":{"rendered":"https:\/\/oilwelldirect.com\/?post_type=product&#038;p=2180"},"modified":"2026-07-28T01:24:21","modified_gmt":"2026-07-28T01:24:21","slug":"rishabh-vl96-ac-ammeter","status":"publish","type":"product","link":"https:\/\/oilwelldirect.com\/ar\/product\/rishabh-vl96-ac-ammeter\/","title":{"rendered":"Rishabh VL96 AC Ammeter, 0\u20132000 A Scale, 2.5 A AC Input, 96 \u00d7 96 mm"},"content":{"rendered":"<h2>Rishabh VL96 AC Ammeter<\/h2>\n<p><strong>Rishabh VL96 AC Ammeter<\/strong> is an analogue panel instrument designed for clear and continuous measurement of alternating current in generator panels, SCR control panels, industrial switchboards and electrical control systems. This customised configuration has a dial marked from 0 to 2000 A AC and a basic full-scale input ranging from 0 to 2.5 A AC.<\/p>\n<p>The instrument uses a moving-coil mechanism combined with an internal rectifier. It responds to the average value of the rectified AC waveform and is calibrated to indicate the corresponding RMS current for a sinusoidal waveform. This construction provides a long, linear scale and improved reading resolution compared with many conventional short-scale analogue instruments.<\/p>\n<p>With a nominal square front dimension of 96 \u00d7 96 mm, the meter is suitable for standard panel layouts. Its knife-edge pointer and 240-degree scale provide operators with an immediate visual indication of load current without requiring auxiliary display programming or menu navigation.<\/p>\n<h2>Rishabh VL96 AC Ammeter with 0\u20132000 A Scale<\/h2>\n<p>The customised dial of the <strong>Rishabh VL96 AC Ammeter<\/strong> is graduated from zero to 2000 amperes AC. This displayed value normally represents the primary-system current rather than the current passing directly through the meter movement.<\/p>\n<p>The basic movement reaches full-scale deflection when the input current reaches 2.5 A AC. Therefore, the meter scale and input have an effective ratio of 800:1. When used with a compatible 2000\/2.5 A current transformer, a primary current of 2000 A produces a 2.5 A secondary signal and moves the pointer to the full-scale 2000 A position.<\/p>\n<p>A correctly matched current transformer or equivalent signal source is essential. Using a CT with a different ratio will cause the indicated primary-current value to be incorrect even when the meter itself is operating normally.<\/p>\n<h2>0\u20132.5 A AC Full-Scale Input<\/h2>\n<p>The specified basic movement input is 0 to 2.5 A AC FSD. FSD means full-scale deflection, indicating that the pointer reaches the maximum 2000 A dial marking when the meter receives its rated 2.5 A AC input.<\/p>\n<p>The <strong>Rishabh VL96 AC Ammeter<\/strong> should be connected only to the intended current-transformer secondary or another compatible low-level AC current source. It should not be connected directly to a 2000 A conductor or high-current generator output.<\/p>\n<p>Current-transformer secondary circuits require particular care. The CT secondary should not be left open-circuit while primary current is flowing, because a potentially dangerous voltage may develop. Installation and replacement should therefore be completed by qualified personnel using approved isolation and shorting procedures.<\/p>\n<h2>Moving-Coil Rectifier Measurement<\/h2>\n<p>The VL series uses a moving-coil rectifier mechanism for AC voltage and current indication. The rectifier converts the alternating input into a unidirectional signal that operates the moving-coil movement.<\/p>\n<p>The manufacturer specifies that AC current instruments are calibrated for RMS indication based on a sinusoidal waveform and are suitable for frequencies from approximately 40 to 1000 Hz. Highly distorted or non-sinusoidal current waveforms may produce a reading that differs from a true-RMS measurement.<\/p>\n<p>This characteristic should be considered in SCR-controlled equipment because phase-controlled or heavily distorted waveforms can affect the indication. Where exact true-RMS measurement of a distorted waveform is required, compatibility with the application should be evaluated before installation.<\/p>\n<h2>240-Degree Linear Scale<\/h2>\n<p>The <strong>Rishabh VL96 AC Ammeter<\/strong> uses an extended 240-degree pointer movement with a linear coarse-and-fine scale. The long scale provides better visual resolution and makes changes in generator or load current easier to observe.<\/p>\n<p>The knife-edge pointer helps reduce reading ambiguity, while the interchangeable dial design supports customised numbering and markings. This allows the 2.5 A meter movement to display a corresponding primary-system range of 0 to 2000 A.<\/p>\n<h2>96 \u00d7 96 mm Panel-Mount Construction<\/h2>\n<p>The instrument has a 96 \u00d7 96 mm front bezel and a moulded square housing suitable for control panels, switchgear panels and machinery consoles. The case is manufactured from flame-retardant, glass-filled polycarbonate, while swivel fixing screws support straightforward panel installation.<\/p>\n<p>The standard size allows the <strong>Rishabh VL96 AC Ammeter<\/strong> to be mounted alongside matching voltmeters, frequency meters, power meters and other analogue instruments in generator and SCR panels.<\/p>\n<p>Before ordering or replacing the meter, users should verify the panel cutout, mounting depth, rear-terminal clearance, terminal arrangement and availability of the optional terminal-protection cover.<\/p>\n<h2>Accuracy and Operating Conditions<\/h2>\n<p>The official VL-series datasheet specifies a standard accuracy class of 1.5 under reference conditions. The stated accuracy assumes the correct mounting position, rated input, suitable ambient temperature and a waveform compatible with the rectifier-type measurement principle.<\/p>\n<p>The normal operating position is vertical. Incorrect mounting angle, external magnetic fields, vibration, waveform distortion or a mismatched CT ratio may affect the displayed current.<\/p>\n<p>The enclosure is specified as IP52 at the case front, while terminal protection depends on whether a rear cover is installed. The meter is intended for indoor panel installation in a suitable electrical enclosure.<\/p>\n<h2>Generator Panel and SCR Applications<\/h2>\n<p>The <strong>Rishabh VL96 AC Ammeter<\/strong> is suitable for compatible generator control panels, SCR panels, power-distribution boards, industrial switchboards and machinery-control systems.<\/p>\n<p>In generator installations, it provides a continuous visual indication of output or load current. Operators can use the analogue pointer to recognise load changes, imbalance indications or abnormal increases in current quickly.<\/p>\n<p>In SCR-controlled systems, the meter may be used to monitor an appropriate AC current signal. Because SCR operation can produce non-sinusoidal waveforms, the reading should be interpreted according to the waveform characteristics and the measuring-system design.<\/p>\n<h2>Important Replacement Requirements<\/h2>\n<p>The <strong>Rishabh VL96 AC Ammeter<\/strong> is a customised panel meter. A replacement should not be selected solely by matching the 96 \u00d7 96 mm size or the 2000 A dial marking.<\/p>\n<p>The correct replacement must match the 0\u20132000 A dial, 0\u20132.5 A AC full-scale input, moving-coil rectifier movement, scale direction, terminal configuration and intended mounting position. The associated CT ratio must also correspond to the meter calibration.<\/p>\n<p>A standard 5 A, 1 A or direct-connected ammeter is not automatically interchangeable with this 2.5 A version. Installing a meter with a different input rating can produce incorrect readings and may overload the meter movement.<\/p>\n<h2>Key Features<\/h2>\n<ul>\n<li>Analogue AC current panel meter<\/li>\n<li>Custom dial marking from 0 to 2000 A AC<\/li>\n<li>Basic movement input from 0 to 2.5 A AC FSD<\/li>\n<li>Effective scale-to-input ratio of 800:1<\/li>\n<li>Moving-coil rectifier measurement mechanism<\/li>\n<li>240-degree linear scale<\/li>\n<li>Knife-edge pointer for clear indication<\/li>\n<li>Standard accuracy class 1.5<\/li>\n<li>96 \u00d7 96 mm square front size<\/li>\n<li>Designed for compatible current-transformer operation<\/li>\n<li>Suitable for generator and SCR panels<\/li>\n<li>Panel mounting with swivel fixing screws<\/li>\n<\/ul>\n<h2>Product Identification<\/h2>\n<ul>\n<li>Manufacturer: Rishabh Instruments<\/li>\n<li>Brand: Rishabh<\/li>\n<li>Series: VL<\/li>\n<li>Model: VL96<\/li>\n<li>Product Type: Analogue AC Ammeter<\/li>\n<li>Dial Range: 0 to 2000 A AC<\/li>\n<li>Basic Movement: 0 to 2.5 A AC FSD<\/li>\n<li>Display Type: Analogue Pointer<\/li>\n<li>Movement Type: Moving-Coil Rectifier<\/li>\n<li>Scale Deflection: 240 Degrees<\/li>\n<li>Scale Characteristic: Linear<\/li>\n<li>Standard Accuracy: Class 1.5<\/li>\n<li>Front Size: 96 \u00d7 96 mm<\/li>\n<li>Application: Generator Panels, SCR Panels and Industrial Switchboards<\/li>\n<\/ul>\n<h2>Manufacturer Technical Information<\/h2>\n<p>For general VL-series dimensions, moving-coil rectifier operation, accuracy, mounting instructions and customised scale options, refer to the official technical documentation published by Rishabh Instruments.<\/p>\n<p>The <strong>Rishabh VL96 AC Ammeter<\/strong> provides a clear analogue current indication when correctly matched with its original 2.5 A signal source, 0\u20132000 A scale calibration and panel wiring.<\/p>\n<p><a href=\"https:\/\/rishabh.co.in\/uploads\/product\/moving-coil-meter-ac-ammeters-and-voltmeters-with-rectifier-240deg-vl-102\/VL_0318RevD1_15NOV2024.pdf\" target=\"_blank\" rel=\"noopener\">View the official Rishabh VL series datasheet<\/a> for VL96 dimensions, moving-coil rectifier operation, AC measurement ranges, accuracy, mounting information and customised dial options.<\/p>\n<p><a href=\"https:\/\/rishabh.co.in\/uploads\/product\/moving-coil-meter-ac-ammeters-and-voltmeters-with-rectifier-240deg-vl-102\/VL_0318RevD1_15NOV2024.pdf\" target=\"_blank\" rel=\"noopener\">View the Rishabh VL Series Official Datasheet<br \/>\n<\/a><\/p>\n<h2 data-start=\"2788\" data-end=\"2818\">Why Choose Oil Well Direct?<\/h2>\n<p data-start=\"2820\" data-end=\"2891\">Oil Well Direct supplies certified drilling equipment spare parts with:<\/p>\n<ul data-start=\"2893\" data-end=\"3042\">\n<li data-start=\"2893\" data-end=\"2933\">\n<p data-start=\"2895\" data-end=\"2933\">17+ years oilfield supply experience<\/p>\n<\/li>\n<li data-start=\"2934\" data-end=\"2962\">\n<p data-start=\"2936\" data-end=\"2962\">Ready stock availability<\/p>\n<\/li>\n<li data-start=\"2963\" data-end=\"2986\">\n<p data-start=\"2965\" data-end=\"2986\">\u0623\u0633\u0639\u0627\u0631 \u062a\u0646\u0627\u0641\u0633\u064a\u0629<\/p>\n<\/li>\n<li data-start=\"2987\" data-end=\"3011\">\n<p data-start=\"2989\" data-end=\"3011\">Fast global shipping<\/p>\n<\/li>\n<li data-start=\"3012\" data-end=\"3042\">\n<p data-start=\"3014\" data-end=\"3042\">Technical sourcing support<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"3044\" data-end=\"3109\"><a href=\"https:\/\/oilwelldirect.com\/ar\/contact-us\/\">Contact us<\/a> today for pricing, availability, and delivery details.<\/p>","protected":false},"excerpt":{"rendered":"<p>Rishabh VL96 AC Ammeter with a customised 0\u20132000 A dial and 0\u20132.5 A AC full-scale input. This 96 \u00d7 96 mm moving-coil rectifier panel meter provides a clear 240-degree linear indication for compatible generator panels, SCR panels, switchboards and industrial control systems using an appropriate current transformer or AC signal source.<\/p>","protected":false},"featured_media":2220,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_brand":[1239],"product_cat":[728,345,788],"product_tag":[1265,1264,1271,1245,1266,1270,1268,1253,1267,1262,1261,1269,1263],"class_list":["post-2180","product","type-product","status-publish","has-post-thumbnail","product_brand-rishabh","product_cat-electronic-components","product_cat-electrical-components","product_cat-rig-electrical-equipment","product_tag-2-5a-ac-ammeter","product_tag-2000a-ammeter","product_tag-240-degree-ammeter","product_tag-96x96-panel-meter","product_tag-analogue-ac-ammeter","product_tag-current-transformer-ammeter","product_tag-generator-panel-ammeter","product_tag-industrial-panel-meter","product_tag-moving-coil-rectifier-meter","product_tag-rishabh-ac-ammeter","product_tag-rishabh-vl96","product_tag-scr-panel-ammeter","product_tag-vl96-ac-ammeter","first","instock","taxable","shipping-taxable","product-type-simple"],"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/oilwelldirect.com\/ar\/wp-json\/wp\/v2\/product\/2180","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/oilwelldirect.com\/ar\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/oilwelldirect.com\/ar\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/oilwelldirect.com\/ar\/wp-json\/wp\/v2\/comments?post=2180"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/oilwelldirect.com\/ar\/wp-json\/wp\/v2\/media\/2220"}],"wp:attachment":[{"href":"https:\/\/oilwelldirect.com\/ar\/wp-json\/wp\/v2\/media?parent=2180"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/oilwelldirect.com\/ar\/wp-json\/wp\/v2\/product_brand?post=2180"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/oilwelldirect.com\/ar\/wp-json\/wp\/v2\/product_cat?post=2180"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/oilwelldirect.com\/ar\/wp-json\/wp\/v2\/product_tag?post=2180"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}